ejmse.2024.09.03.201

THE INFLUENCE OF CHEMICAL AGENTS ON THE TECHNICAL CHARACTERISTICS AND SAFETY OF PROTECTIVE EQUIPMENT AGAINST ELECTRIC SHOCK

European Journal of Materials Science and Engineering, Volume 9, Issue 3, 2024
PDF Full Article, DOI: 10.36868/ejmse.2024.09.03.201, pp. 201-208

Georgeta BUICĂ 1, Anca Elena ANTONOV 1, Constantin BEIU1,*, Remus DOBRA2, Dragoș PĂSCULESCU33, Lucian – Șerban CUESDEANU4, Marius George BUICĂ 1
1 National Research and Development Institute for Labor Protection “Al. Darabont”, Bucharest, Blvd. Ghencea no. 35A, sect. 6, Romania
2 “1 Decembrie 1918”, Gabriel Bethlen Str. No. 5, Alba Iulia, Alba, Romania
3 University of Petrosani, 20 Universitătii st., Petrosani 332006, Hunedoara, Romania
4 “SC Nakita Prod Comimpex SRL”, 1 Decembrie 1989 Str. No. 150, Targu Mures, Romania
* Corresponding author: costinbeiu01@gmail.com

Abstract
The research project’s primary goals were to develop occupational risk management protocols for people who perform maintenance tasks on electrical installations and, in turn, to develop new work tools designed to protect workers in those installations. The research project’s findings are presented in this paper. In order to check the behaviour of the safety characteristics of the protective equipment material under certain influence of professional risk factors, protective equipment materials were subject to tests. The components of in use or new electro-insulating equipment, were evaluated through sampling. Electro-insulating materials underwent dielectric, mechanical, attrition testing, and chemical agent application. The findings revealed the weakness of some electrical insulating materials whose declared duration of use exceeded five years after commissioning, necessitating the assessment of new technical standards for health and safety workplace.

Keywords: electro-insulating material, chemical agent, prototype

References:
[1] INCDPM, Project POC Partnership for the transfer of knowledge and the development of research related to the assessment and prevention of occupational risks that can lead to disasters (PROC), ID/Cod SMIS 2014+: POC P_40_182/111954, 2022-2023.
[2] INCDPM, Study on the identification of occupational hazards in electrical installations in order to ensure the safety and health of workers for 35 workplaces (2021);
[3] G. Buică, Contributions of diagnostic methods of safety and health at work in electrical installations, PhD Thesis, Universitas Petroşani, 2010, pp.70 – 149.
[4] V. M. Pasculescu, E. Ghicioi, L. Ioana Tuhut, A. B. Simon-Marinica D. Pasculescu, Discharge and atmospheric dispersion modelling in case of hazardous material releases, MATEC Web of Conferences, 354(00009), 2022, pp. 1-7.
[5] G. Buică, A.E. Antonov, C. Beiu, D. Pasculescu, C. Sipos, Study on behaviour of electrical insulating materials combined with conductive elements, ICIR Euroinvent 2022, Iasi, Romania, and IOP Conf. Series: Materials Science and Engineering 1251, 2022, pp. 1-10.
[6] T. Niculescu, D. Pasculescu, V.M. Pasculescu, I.O. Stoica , Evaluation of electrical parameters of intrinsic safety barriers of the electrical equipment intended to be used in atmospheres with explosion hazard, Int. Multidiscip. Sci. GeoConf. Surv. Geol. Min. Ecol. Manag, Albena, Bulgaria, 2014, pp.169-76.
[7] M. Haiducu, R.A. Ștepa, SD SmartRisk, a decision support system to help non-expert decision makers in case of chemical accidents, Romanian Journal of Ecology & Environmental Chemistry, 4(2), 2022, pp. 156 – 163.
[8] F. G. Popescu, D. Pasculescu, M. Marius, V.M. Pasculescu, A. Tatar, N.D. Fita, T. Lazar, Principles of effective energy management and power control system, Annals of the University of Petrosani, Electrical Engineering, 24, 2022, pp. 109 -116.
[9] R. Dobra, D. Pasculescu, G. Marc, M. Risteiu, A. Antonov, Designing and Implementation a Lab Testing Method for Power Cables Insulation Resistance Testing According with STAS 10411-89, SR EN ISO/CEI/17025/2005, IOP Conf. Series: Materials Science and Engineering, 209, 2017, pp.1-6.
[10] M. Haiducu, R.A. Ștepa, R.E Chiurtu, E.Schmitz-Felten, Considerations regarding the development of useful tools for managing chemical risks, Environmental Engineering and Management Journal, 18(4), 2019, pp. 825-830.
[11] V.M. Pasculescu. N.I. Vlasin, I. Nicolae, M.C. Suvar, E. Ghicioi, D. Florea, Considerations on impact resistance tests for electrical equipment used in explosive atmospheres, SGEM Albena, Bulgaria, Vol. II, 2016, pp. 1-8.
[12] M. Nabiałek, K. Błoch, M. Szota, A.V. Sandu, Structure and Magnetic Properties of Composite Toroids Powder Casted, Materiale Plastice, 54(3), 2017, pp. 491-494.
[13] A. Tatar, D. Pasculescu, M.D. Marcu, T. Lazar, F. G. Popescu, Electric power production and national energy security considerations, Annals of the University of Petrosani, Electrical Engineering, 24, 2022, pp. 5 -14.
[14] A.D. Handra, D. Pasculescu, F.G. Popescu, Measuring the level of the products quality from energetic point of view, Annals of ‘Constantin Brancusi’ ”University of Targu Jiu”, Engineering Series, no. 1, 2020, pp. 54-60.
[15] R. M. Iordache, D. Mihăilă, D, C, Darabont, V. Petreanu Analysis of mental effort and its subjective and psychophysiological indicators for gas transport dispatchers, Human Systems Management, 42(3), 2022, pp. 1-9.
[16] https://proc.inpm.ro/ [Accessed 22.05.2023)]